{"id":6329,"date":"2025-12-04T16:12:13","date_gmt":"2025-12-04T15:12:13","guid":{"rendered":"https:\/\/b2w.aquasant.com\/produkt\/interface-sensor-overview-stmd\/"},"modified":"2026-01-22T10:59:39","modified_gmt":"2026-01-22T09:59:39","slug":"interface-level-sensor-overview-stmd","status":"publish","type":"produkt","link":"https:\/\/b2w.aquasant.com\/en\/product\/interface-level-sensor-overview-stmd\/","title":{"rendered":"STMd SB TN | Impedance bar probe for interface level &#8211; Overview"},"content":{"rendered":"\n<ul class=\"wp-block-list is-style-list-var-2\">\n<li><em>Continuous, impedance-based interface level measurement between two immiscible liquids (e.g. organic\/aqueous) in decanters and separators<\/em><\/li>\n\n\n\n<li><em>Interface level bar probes Industry Process measurement technology for automation<\/em><\/li>\n\n\n\n<li><em>Measuring principle: Impedance measurement via real-time recording of electrical properties (conductivity, dielectric constant), non-capacitive.<\/em><\/li>\n\n\n\n<li><em>Used for precise phase position determination in emulsions, phase inversion and changing process conditions<\/em><\/li>\n\n\n\n<li><em>Continuous real-time measurement of the interface height without moving parts; insensitive to deposits<\/em>and coatings.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-bottom:var(--wp--preset--spacing--60)\">Fast interface level &#8211; measurement for demanding chemical processes with Swiss precision<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Process-specific rod probes for continuous real-time separation layer detection<\/h3>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9a734125 wp-block-columns-is-layout-flex\" style=\"margin-bottom:var(--wp--preset--spacing--70)\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:50%\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;69e4e4f6b5faa&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"69e4e4f6b5faa\" class=\"wp-block-image size-medium is-resized wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"258\" height=\"300\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/Aquasant_Trennschicht-Stabsonde-STMd-258x300.png\" alt=\"Various interface rod probes for continuous phase separation of the Aquasant\" class=\"wp-image-6593\" style=\"width:239px;height:auto\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"state.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<p>The Aquasant rod probe is the reliable partner for precise <a href=\"https:\/\/b2w.aquasant.com\/en\/anwendung\/interface-measurement\/\">interface measurement<\/a> and continuous phase separation in complex chemical applications. Developed for use in decanters and separators, this bar probe impresses with its robust design made of stainless steel, alloy or tantalum and a highly resistant coated measuring electrode.<\/p>\n\n\n\n<p>Especially in processes with emulsions and phase inversions, which often occur in chemical extractions, the rod probes ensure reliable, long-lasting performance and measurement accuracy.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"block-faqs\">\n        <details>\n        <summary>Is the Aquasant sensor  a capacitive interface level measurement?<\/summary>\n        <div class=\"faq-answer\">The Aquasant interface probes (e.g. STMd, SEMd bar probes) do not work capacitively, but impedance-based. Aquasant uses an impedance measurement method based on defined AC voltage signals, which evaluates the following parameters:\r\n<ul class=\"wp-block-list\">\r\n \t<li>Complex impedance (real and imaginary component)<\/li>\r\n \t<li>Conductivity (for conductive phases)<\/li>\r\n \t<li>dielectric properties of the two phases<\/li>\r\n<\/ul>\r\nThis allows stable, low-drift and precise interface measurement even in demanding media such as solvents, aqueous phases, emulsions or highly fluctuating process conditions.<\/div>\n    <\/details>\n        <details>\n        <summary>What does an impedance interface level sensor measure?<\/summary>\n        <div class=\"faq-answer\">An impedance bar probe measures the electrical impedance between two immiscible liquids. This enables it to detect the exact height of the interface in decanters or separators. The measurement is continuous, stable and independent of density differences.<\/div>\n    <\/details>\n        <details>\n        <summary>How does the impedance interface measurement work?<\/summary>\n        <div class=\"faq-answer\">The measuring principle is based on various electrical properties of the process media. The probe measures conductivity and dielectric constant. Dual-circuit probes automatically compensate for product changes and ensure reliable interface measurement with changing media.<\/div>\n    <\/details>\n        <details>\n        <summary>Does the probe detect interfaces despite emulsions?<\/summary>\n        <div class=\"faq-answer\">Yes, impedance bar probes detect the interface even with emulsion formation, mixing zones or turbulence. The measurement remains stable and provides clear interface values, even in demanding processes with variable phase purity.<\/div>\n    <\/details>\n        <details>\n        <summary> What are the advantages of an impedance probe compared to floats?<\/summary>\n        <div class=\"faq-answer\">Impedance probes measure continuously, are insensitive to deposits and function independently of the liquid density. They have no moving parts and offer significantly higher process reliability than floats or pressure sensors.<\/div>\n    <\/details>\n        <details>\n        <summary>How easy is commissioning?<\/summary>\n        <div class=\"faq-answer\">The probes are plug-and-process-capable. After installation, they start up without time-consuming calibration. Factory-preset parameters enable immediate, stable and low-maintenance measurement.<\/div>\n    <\/details>\n        <details>\n        <summary>Are the probes chemically resistant?<\/summary>\n        <div class=\"faq-answer\">Yes, Aquasant probes are available in materials such as stainless steel, Hastelloy or completely PTFE. This makes them suitable for aggressive, corrosive or changing media in chemical, pharmaceutical and biotech processes.<\/div>\n    <\/details>\n        <details>\n        <summary>Does the measurement work in batch and continuous decanters?<\/summary>\n        <div class=\"faq-answer\">Impedance measurement is suitable for both operating modes: continuous systems benefit from permanent interface monitoring, batch processes from precise separation stops. This improves product purity and reduces process time.<\/div>\n    <\/details>\n        <details>\n        <summary>Does the measurement react to changes in density?<\/summary>\n        <div class=\"faq-answer\">Only minimally. The probe identifies the interface via electrical properties instead of density. As a result, the measurement remains stable even if the temperature or composition changes the density.<\/div>\n    <\/details>\n        <details>\n        <summary>How much maintenance is required?<\/summary>\n        <div class=\"faq-answer\">The maintenance effort is very low. As there are no mechanical components and the measuring principle is insensitive to deposits, the probes run for many years without service intervention.<\/div>\n    <\/details>\n        <details>\n        <summary>What criteria determine the right choice of sensor?<\/summary>\n        <div class=\"faq-answer\">Important factors are Chemical resistance, temperature and pressure range, media change, emulsion behavior, installation length, process connection and Ex approval (e.g. Ex ia). These factors ensure reliable, long-term interface measurement.<\/div>\n    <\/details>\n    \n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Why is precise detection with the interface level bar probe crucial?<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Product phase mixing leads to considerable costs and contamination of the organic phase<\/h3>\n\n\n\n<p>Process optimization is essential for time-saving, efficient production. The degree of automation with the continuous interface rod probe in the decanter allows the continuous product separation to be operated autonomously. The continuous feed flow into the decanter is controlled by the overflow and the regulated outlet via a control valve in the lower phase.  <\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-0427d430 wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:0;padding-top:var(--wp--preset--spacing--60);padding-bottom:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/doc.aquasant.com\/Application\/VDP-Applikation%20Trennschichtniveau.pdf\">Are you interested? Download technical data sheet <\/a><\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages of the interface level sensor for maximum process control<\/h2>\n\n\n\n<p>The continuous interface rod probe type: STMd-R, ensures precise detection and control of the phase height in the separator. This automatic adaptation to specific process requirements enables you to optimally control the phase separation and thus significantly increase the efficiency of your decanter processes. Seamless integration into your existing process infrastructure ensures minimal downtime and rapid implementation.  <\/p>\n\n\n\n<h3 class=\"wp-block-heading\">General advantages<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Highest measuring accuracy for any conductivity<\/li>\n\n\n\n<li>Real-time interface measurement<\/li>\n\n\n\n<li>Insensitive to emulsions &amp; coatings<\/li>\n\n\n\n<li>Ex ia certified for zone 0\/1 for substance group IIC T6<\/li>\n\n\n\n<li>Maintenance-free thanks to optimized design<\/li>\n\n\n\n<li>Customized length (up to 6 m)<\/li>\n\n\n\n<li>Ideal in mono and multi-purpose systems<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">High-quality materials for extreme conditions<\/h3>\n\n\n\n<p>The interface rod probes are designed to function reliably even under extreme conditions. The combination of stainless steel or alloy and an FFKM double sealing system and a Teflon measuring electrode offers exceptional resistance to aggressive chemical environments. This makes the STMd-R sensor the ideal choice for demanding applications where reliability and longevity are critical.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-a89b3969 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/b2w.aquasant.com\/en\/contact-form-meeting-request\/\">Request to book a meeting<\/a><\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-28f84493 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:30%\"><div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;imageId&quot;:&quot;69e4e4f6b8ff3&quot;}\" data-wp-interactive=\"core\/image\" data-wp-key=\"69e4e4f6b8ff3\" class=\"alignleft size-large is-resized wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"411\" height=\"1024\" data-wp-class--hide=\"state.isContentHidden\" data-wp-class--show=\"state.isContentVisible\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"http:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/12357-1-STMd-400-270-SB-R-TN-ES4-K-ANSI2-C-Datenblatt-411x1024.png\" alt=\"\" class=\"wp-image-6547\" style=\"width:200px;height:auto\" srcset=\"https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/12357-1-STMd-400-270-SB-R-TN-ES4-K-ANSI2-C-Datenblatt-411x1024.png 411w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/12357-1-STMd-400-270-SB-R-TN-ES4-K-ANSI2-C-Datenblatt-120x300.png 120w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/12357-1-STMd-400-270-SB-R-TN-ES4-K-ANSI2-C-Datenblatt-768x1916.png 768w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/12357-1-STMd-400-270-SB-R-TN-ES4-K-ANSI2-C-Datenblatt-616x1536.png 616w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/12357-1-STMd-400-270-SB-R-TN-ES4-K-ANSI2-C-Datenblatt-821x2048.png 821w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2025\/12\/12357-1-STMd-400-270-SB-R-TN-ES4-K-ANSI2-C-Datenblatt-scaled.png 1026w\" sizes=\"auto, (max-width: 411px) 100vw, 411px\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"state.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"state.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:70%\">\n<h3 class=\"wp-block-heading\">Customized selection options<\/h3>\n\n\n\n<p class=\"has-text-align-left\"><strong>The process conditions set the path. <\/strong><br>The chemical product type and process parameters such as pressure and temperature are decisive for probe materialization and dimensioning. <br>Decanter dimensions determine the process connection, active measuring length and total length. The basic requirement of 100% product coverage of the active measuring range must be met.<br>The 4-rod reference electrode includes the measuring field lines of the impedance measurement.  <\/p>\n\n\n\n<div class=\"wp-block-buttons is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-fc4fd283 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/b2w.aquasant.com\/blogbeitrag-biotechnologischer-produktionsprozess-trennschichtdetektion-auswaschprozessen\/\">Blog article Interface detection<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:71px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Specifications<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Physical measuring principle: <a href=\"https:\/\/b2w.aquasant.com\/impedanz-messprinzip\/\" data-type=\"page\" data-id=\"3687\">Impedance<\/a><\/li>\n\n\n\n<li>Process connections: Flanges or threads (metric\/inch)<\/li>\n\n\n\n<li>Process pressure: 0.5 to +40 bar<\/li>\n\n\n\n<li>Measuring range: 40 to 3000 mm<\/li>\n\n\n\n<li>Temperature: -20 to +170 \u00b0C<\/li>\n\n\n\n<li>2-wire technology<\/li>\n\n\n\n<li>ATEX Ex ia-approved for zone 0\/1<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Application variants of interface level sensor<\/h2>\n\n\n\n<p>Aquasant sensors are designed and produced exclusively in-house. The process conditions and products of the system are taken into account. We define the optimum sensor through personal consultation and process queries.  <\/p>\n\n\n\n<ul class=\"wp-block-list is-style-list-var-3\">\n<li><a href=\"https:\/\/b2w.aquasant.com\/produkt\/trennschicht-stabsonde-sk2md-sb-r-g\/\">High-temperature ceramic SKMd rod probe <\/a>up to 170\u00b0C<\/li>\n\n\n\n<li><a href=\"https:\/\/b2w.aquasant.com\/produkt\/trennschicht-stabsonde-stmd-sb-t-dn\/\">Full PTFE STMd-T rod probe<\/a> for aggressive products<\/li>\n\n\n\n<li><a href=\"https:\/\/b2w.aquasant.com\/produkt\/trennschicht-stabsonde-sgk-sb-g-sl\/\">SGK rod probe mini glass sensor<\/a> for mixer-settler applications<\/li>\n\n\n\n<li><a href=\"https:\/\/b2w.aquasant.com\/produkt\/trennschicht-stabsonde-stm-sb-t-2tn-dn\/\">Product compensated STMd rod probes<\/a> of one phase<\/li>\n\n\n\n<li><a href=\"https:\/\/b2w.aquasant.com\/produkt\/trennschicht-stabsonde-semd-sb-r-g\/\">SEM rod probe with glass-lined measuring electrode<\/a> for high temperature application<\/li>\n\n\n\n<li><a href=\"https:\/\/b2w.aquasant.com\/produkt\/batch-trennschichtdetektion-klammersonde-fagl-se-r-u-ef\/\">Interface detection clamp sensor<\/a> for glass apparatus<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Areas of application<\/h2>\n\n\n\n<p>Continuous separation processes of organic and aqueous phases in decanters and columns in the chemical and pharmaceutical industries, oil-water separation in refineries<\/p>\n\n\n    <ul class=\"product-segments\">\n\n                    <li class=\"product-segment badge badge-variant-1\">Chemicals<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Petro Industry<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Pharmaceuticals<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Production<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Refinery<\/li>\n            <\/ul>\n\n\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-default\"\/>\n\n\n<div class=\"wp-block-image is-style-rounded\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"http:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen.jpg\" alt=\"Managing Director Roger Inauen at Aquasant in Bubendorf\" class=\"wp-image-4078\" style=\"width:154px;height:auto\" srcset=\"https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen.jpg 500w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen-300x300.jpg 300w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><figcaption class=\"wp-element-caption\">Roger Inauen<\/figcaption><\/figure>\n<\/div>\n\n\n<blockquote class=\"wp-block-quote has-text-align-center is-style-large is-layout-flow wp-block-quote-is-layout-flow\">\n<p>&#8220;Learn more about precise interface measurement and optimize your phase separation with the STMd bar probe. <strong>Contact us<\/strong> now for an individual consultation and maximize the efficiency of your chemical processes.&#8221;<\/p>\n<cite>&#8211; Managing Director<\/cite><\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-default\"\/>\n\n\n\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-1bd719e0 wp-block-group-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--60)\">\n<div class=\"wp-block-buttons is-layout-flex wp-container-core-buttons-is-layout-6515429c wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60);padding-top:0;padding-bottom:0\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/b2w.aquasant.com\/en\/your-contact-at-aquasant\/\">Request feasibility analysis for free<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:61px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"margin-bottom:var(--wp--preset--spacing--50)\">Overview of the various interface level sensor<\/h2>\n\n\n    <div class=\"thema-background-qualities-inner product-tiles\">\n        <h3 class=\"no-results\">\n            No products were found for your selection.        <\/h3>\n    \n        \n<a href=\"https:\/\/b2w.aquasant.com\/en\/product\/stmd-sb-t-tn-impedance-rod-probe-for-interface\/\" class=\" tile product-tile \" data-id=\"7484\" >\n\n    \n    <img \n        decoding=\"async\" \n        src=\"https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/12054-STMd-480-260-SB-T-TN-DN_Stabsonde_Aquasant-Sensor-337x1024.png\" \n        class=\"attachment-post-thumbnail size-post-thumbnail wp-post-image\" \n        alt=\"\"\n        title=\"Aquasant Trennschicht-Stabsonde\nSensor Typ: STMd-480-260-SB-T-TN-DN\"\n    \/>\n    <h3 class=\"title\">STMd SB T TN DN<\/h3>\n    <div class=\"text\">Interface - level full Teflon rod probe in decanter for aggressive liquids<\/div>\n    <div class=\"app-button margintop20\">\n        <div class=\"button\">View details<\/div>\n    <\/div>\n<\/a>\n\n\n\n    <\/div>\n\n    \n\n\n\n<p><\/p>\n","protected":false},"author":3,"featured_media":5090,"menu_order":1,"template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"","_seopress_titles_title":"Impedance bar probe | Precise interface level sensors for decanters \u2013 Aquasant","_seopress_titles_desc":"Discover Aquasant impedance rod probes for precise phase separation in decanters. Chemical-resistant, Ex ia-approved, and available in custom lengths. Ideal for chemical and pharmaceutical applications.","_seopress_robots_index":"","produkt_segmentierung":["Chemie","Petro","Pharma","Produktion","Raffinerie"],"footnotes":""},"class_list":["post-6329","produkt","type-produkt","status-publish","has-post-thumbnail"],"acf":[],"_links":{"self":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt\/6329","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt"}],"about":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/types\/produkt"}],"author":[{"embeddable":true,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/users\/3"}],"version-history":[{"count":32,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt\/6329\/revisions"}],"predecessor-version":[{"id":7932,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt\/6329\/revisions\/7932"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/media\/5090"}],"wp:attachment":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/media?parent=6329"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}