{"id":7484,"date":"2025-11-18T12:41:18","date_gmt":"2025-11-18T11:41:18","guid":{"rendered":"https:\/\/b2w.aquasant.com\/produkt\/stmd-sb-t-tn-impedance-rod-probe-for-interface\/"},"modified":"2026-01-20T17:46:13","modified_gmt":"2026-01-20T16:46:13","slug":"stmd-sb-t-tn-impedance-rod-probe-for-interface","status":"publish","type":"produkt","link":"https:\/\/b2w.aquasant.com\/en\/product\/stmd-sb-t-tn-impedance-rod-probe-for-interface\/","title":{"rendered":"STMd SB T TN | Impedance rod probe for interface"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>Efficient phase separation under extreme conditions &#8211; the STMd-T rod probe<\/strong><\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Typical use of the application for phase separation<\/h3>\n\n\n\n<p>Highest reliability in phase separation for demanding chemical processes. The rod probe type: STMd-T from Aquasant is the ideal solution for process engineers who require the highest precision and reliability in <a href=\"https:\/\/b2w.aquasant.com\/application\/kontinuierliche-trennschichtmessung\/\" data-type=\"link\" data-id=\"https:\/\/b2w.aquasant.com\/application\/kontinuierliche-trennschichtmessung\/\">interface measurement<\/a> in demanding chemical processes. Thanks to its full PTFE design, this probe is particularly suitable for use in environments with aggressive chemicals.  <\/p>\n\n\n\n<p>This advanced probe ensures continuous phase control in glass-lined or PTFE-lined decanters by precisely <a href=\"https:\/\/b2w.aquasant.com\/impedanz-messprinzip-sensoren\/\" data-type=\"page\" data-id=\"3687\">measuring the phase height using impedance measurement<\/a>. Whether emulsions, phase inversions or other complex process conditions &#8211; the STMd-T ensures reliable and optimal phase separation. <\/p>\n\n\n    <ul class=\"product-segments\">\n\n                    <li class=\"product-segment badge badge-variant-1\">Chemicals<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Petro Industry<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Pharmaceuticals<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Pilotplan<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Production<\/li>\n                    <li class=\"product-segment badge badge-variant-1\">Refinery<\/li>\n            <\/ul>\n\n\n\n\n\n<h3 class=\"wp-block-heading\"><strong>High-quality materials for extreme conditions<\/strong><\/h3>\n\n\n\n<p>Adaptability is the key to success in the chemical industry. That&#8217;s why the STMd-T offers a customized sensor design that is precisely tailored to your process requirements to ensure maximum results and process reliability. The combination of stainless steel, Teflon sheathing and the FFKM (Chemraz) double sealing system ensures that the probe performs reliably even under extreme chemical conditions.  <\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Precision in the measurement and differentiation of liquid phases<\/strong><\/h3>\n\n\n\n<p>With the ability to accurately measure <a href=\"https:\/\/b2w.aquasant.com\/impedanz-messprinzip\/\" data-type=\"page\" data-id=\"3687\">impedance<\/a>, conductivity and dielectric constant (DK) as a sum signal, the STMd-T rod probe allows you to clearly distinguish between different liquid interfaces &#8211; from insulating to highly conductive products. This provides you with valuable data that can significantly improve the efficiency and quality of your processes. <\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Specifications<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Physical measuring principle: <a href=\"https:\/\/b2w.aquasant.com\/impedanz-messprinzip\/\" data-type=\"page\" data-id=\"3687\">Impedance<\/a><\/li>\n\n\n\n<li>Process connections: Flanges or threads (metric\/inch)<\/li>\n\n\n\n<li>Process pressure: 0.5 to +40 bar<\/li>\n\n\n\n<li>Measuring range: 40 to 3000 mm<\/li>\n\n\n\n<li>Temperature: -20 to +170 \u00b0C<\/li>\n\n\n\n<li>2-wire technology<\/li>\n\n\n\n<li>ATEX<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/b2w.aquasant.com\/en\/contact-form-meeting-request\/\">Request to book a meeting<\/a><\/div>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-default\"\/>\n\n\n<div class=\"wp-block-image is-style-rounded\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"500\" src=\"http:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen.jpg\" alt=\"\" class=\"wp-image-4078\" style=\"width:154px;height:auto\" srcset=\"https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen.jpg 500w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen-300x300.jpg 300w, https:\/\/b2w.aquasant.com\/wp-content\/uploads\/2024\/08\/aquasant_Roger-Inauen-150x150.jpg 150w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/figure>\n<\/div>\n\n\n<blockquote class=\"wp-block-quote has-text-align-center is-style-large is-layout-flow wp-block-quote-is-layout-flow\">\n<p>&#8220;Learn more about precise interface measurement and optimize your phase separation with the STMd-R rod probe. <strong>Contact us<\/strong> now for an individual consultation and maximize the efficiency of your chemical processes.&#8221;<\/p>\n<cite>&#8211; Roger Inauen<\/cite><\/blockquote>\n\n\n\n<hr class=\"wp-block-separator has-css-opacity is-style-default\"\/>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-container-core-buttons-is-layout-6515429c wp-block-buttons-is-layout-flex\" style=\"margin-top:var(--wp--preset--spacing--60);margin-bottom:var(--wp--preset--spacing--60);padding-top:0;padding-bottom:0\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/b2w.aquasant.com\/en\/your-contact-at-aquasant\/\">Request feasibility analysis for free<\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"author":3,"featured_media":5083,"menu_order":2,"template":"","meta":{"_acf_changed":false,"_seopress_robots_primary_cat":"","_seopress_titles_title":"Continuous interface measurement \u25bd Sensor, PTFE, &lt;170\u00b0C","_seopress_titles_desc":"Decanter rod probe for automatic control of separation layers, continuous phase separation during extractions. Phase inversion \u2713 Mulm layers \u2713 Contamination","_seopress_robots_index":"","produkt_segmentierung":["Chemie","Petro","Pharma","Pilotplan","Produktion","Raffinerie"],"footnotes":""},"class_list":["post-7484","produkt","type-produkt","status-publish","has-post-thumbnail"],"acf":[],"_links":{"self":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt\/7484","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt"}],"about":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/types\/produkt"}],"author":[{"embeddable":true,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/users\/3"}],"version-history":[{"count":7,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt\/7484\/revisions"}],"predecessor-version":[{"id":7860,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/produkt\/7484\/revisions\/7860"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/media\/5083"}],"wp:attachment":[{"href":"https:\/\/b2w.aquasant.com\/en\/wp-json\/wp\/v2\/media?parent=7484"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}