Oil and solvent leaks are measured on the water surface
Area of application
Continuous separation layer height of petrochemical products on water “crude oil in drain water” or rainwater monitored in the collecting basin or oil separator shaft with the proven impedance float system controls the slide valve to the ORB for the discharge of place water in the event of an accident. The float is equipped with a rod probe with MTI on-site measuring electronics and is used in Ex zone 1 ia IIB. The signal is routed to the MAT control unit in the non-hazardous area using 2-wire technology.
The surface oil sensor detects an oil layer thickness of 1 mm or more on the rainwater.
Specifications
- Physical measuring principle: Impedance
- Float stroke length freely selectable
- Plastic housing
- Float in protective tube with strong current
- Protective pipe with Ex heating tape for outdoor use
- Ex zone 1 or special version in zone 0
- in the pump shaft of basins in tank farms
- Oil separator shaft at filling stations and washing areas
- Monitoring of waste water
- ATEX
Info
Technical specification
Documentation
Accessoires
Info
Advantages
- Changing water conductivity and contamination is compensated for
- Continuous height measurement of the interface
- No moving parts in the measurement
- Largely maintenance-free
- Plug&Process Technology (PPT) no commissioning
Control units
MAT 4160
The Generalist MAT can be used for everything from level measurement to monitoring and detection. The first and second measuring circuits have the same functionality. The evaluation electronics not only serve as a power supply unit in 2-wire technology, but also contain the intelligence for data processing.
Your benefit: High cost-effectiveness and investment security thanks to a long service life.
- Universally applicable, reduces storage costs
- With 1 or 2 measuring inputs
- Fault visualization, fault messages can be set to analogue output mA output and limit value simulation
- Drainage of rainwater in petrochemical storage tanks
Ex version: Gas II (2) G [Ex ia Gb] IIC EMC STS 024 CE ****

Technical specification
Dimensionen
Sonden-Material
Messelektronik
Schutzart
Umgebungstemperatur
Messprinzip
Prozess-Temperaturbereich
Prozess-Druckbereich
Dichtungen
Messelektroden-Material
max. Messlänge
Messbereich
Leitfähigkeitsbereich
F3: 0..4000 µS/cm
Integrationszeit
Geltungsbereich
IEC / weltweit
UKCA Grossbritanien
Zertifikate
Tool certificate 2.2 (EN 10204)
Inspection certificate 3.1
Ausgang
MTI: Pulse
Documentation
Downloads
Flyer surface detection
Probe data sheet STMk
Operating instructions short MAT
Operating instructions MAT/MLS
Ex-documentation
Languages DE/FR/(IT)/EN
Accessoires
- Cable guide with mounting plate
- Boom bracket Wall mounting
- MAT4110 Evaluation unit
- MRM 2 Monorack
- MTI50/0 AEE2